Description
1.Inch touch screen , all commends in one touch
2.Easy – to –use software
3.LED- excitation and PD –detection,7 second top optical scanning
4.Outstanding and powerful data analysis functions
1.Inch touch screen , all commends in one touch
2.Easy – to –use software
3.LED- excitation and PD –detection,7 second top optical scanning
4.Outstanding and powerful data analysis functions
| Model |
QTC966G |
QTC966 |
QTC964G |
QTC964 |
| Thermal Block | ||||
| Sample capacity (wells) |
96 |
|||
| Reaction volume |
0-100µL |
|||
| consumables |
0.2ML 96-Well Plates (unskirt): 0.2ml 8-strip tubes,0.2ml PCR single tube (Optical flat cap,clear,frosted, white tube) |
|||
| Temperature range |
0˚C.100 ˚C |
|||
| Heating / cooling method |
Pettier |
|||
| Max heating rate |
6.1˚C/sec |
|||
| Average heating rate |
4.5˚C/sec |
|||
| Max cooling rate |
5.0˚C/sec |
|||
| Average cooling rate |
2.8˚C/sec |
|||
| Temperature accuracy |
±0.1˚C |
|||
| Temperature uniformity |
±0.1˚C |
|||
| Gradient Range |
1˚C -40 ˚C |
N / A |
1˚C – 40˚C |
N / A |
| Gradient block |
12 row |
12 row |
||
| Special temperature protocol |
Gradient PCR,Long PCR,Touch Down PCR |
Long PCR,Touch Down PCR |
Gradient PCR,Long PCR,Touch Down PCR |
Long PCR,Touch Down PCR |
|
Heat Lid |
||||
| Temperature range |
Room temperature 110˚C |
|||
|
Optical System |
||||
| Excitation Source |
photodiode |
|||
| Detection Position |
Excitation and scan at top |
|||
| Detection method |
6 channels scanning at the same time , no edge effect |
|||
| Detection time |
7 seconds for 96 wells for all channels |
|||
| Range of excitation / emission wavelengths (nm) |
1.465/510(FAM,SYBR Green I,SYTO9,EvaGreen) 2. 527 / 563 (HEX,VIC,TET,JOE) 3.580 / 616 (ROX,Texas Red ) 4.632 / 664 (Cy5) 5.680 / 730 (Alexa Fluor680) 6.465 / 616 (FRET) |
1.465/510(FAM,SYBR Green I,SYTO9,EvaGreen,LC Green) 2. 527 / 563 (HEX,VIC,TET,JOE) 3.580 / 616 (ROX,Texas Red ) 4.632 / 664 (Cy5 |
||
| Probe |
Taqman Probe, Molecular beacons probe ,Scorpion probe .FRET |
Taqman Probe, Molecular beacons probe ,Scorpion probe |
||
| multiplexing |
Up to 6 targets |
Up to 4 targets |
||
| Fluorescence Linearity |
r≥0.990 |
|||
| Fluorescence Dynamic Range |
Adjustable |
|||
|
Performance |
||||
| Sample Linearity |
/r/≥0.999 |
|||
| Sample repeatability |
CT value CV≤ 0.5 % |
|||
| Sample Dynamics Range |
1-1010 copies |
|||
|
Software Functions |
||||
| Data Analysis modes |
Qualitative analysis, absolute quantification, Relative. quantification, Genotyping analysis , Endpoint analysis , Melt curve analysis ,High Resolution Melting |
|||
| Control modes |
1.10.4 touch screen 2.PC direct control 3. WLAN control (One PC can control max 10 units , and decice can be controlled by any PC in the WLAN |
|||
| Sample Drawer |
Touch screen commend |
|||
| Data Storage |
Upload and download through USB disk , 1000 result can be stored in machine |
|||
| Power failure protection |
Automatically start running experiments after power supply , no need wait PC software |
|||
| Customize Report |
Templates reserved, report can customized |
|||
| Administration Management |
Administrator can set function limits for users |
|||
| Transport Locker |
Automatically detect transport locker |
|||
| Fault Management |
Fault report and analysis, solution instruction |
|||
| LIS connection |
CSV , Excel ,TXT Format data output ,open port for LIS connection |
|||
|
Other |
||||
| PC operating system |
Win7 , Win 10 |
|||
| Communication Port |
1 Ethernet and 3 USB |
|||
| Footprint (WxDxH) |
355mmX480mmX485mm |
|||
| Weight |
30kg |
|||
| Power usage |
AC100 TO 125V/200 TO 240V(50/60 Hz) |
|||
| Power consumption |
900VA |
|||
| Work environment |