FAE-4 Fully automated ELISA processor

QUICK OVERVIEW

Product Code: 845
Brand: Elisa System

FAE-4


Share this product on social networks

  • 1 Robotic hand.
  • 2 Pipetting probe, 1ul stepping (1000ul volumes).
  • Total 25 racks, arbitrary rack can be defined as sample or reagent on the software.
  • 4 units 96 well microplates (pipetting,incubator,reading).
  • 1 unit independent washer &reader( two 8 nozzle manifolds).

Specification

Model FAE-4 FAE-4
Sample pipetting unit Sample rack 24 sample tubes/rack, at most 25 racks
Primary sample tubes 11.5-13mm
Pipetting 8ul~1000ul, (10ul) CV<5%
Time to dispense 15 minutes (typical)^100ul of 96 samples to plate from sample tubes or dilution tubes.
Dispensing system 1 aspirating-dispensing probe with X-Y-Z movement ;dilution systemwith a syringe of 1000ul, continuous flow washing station.
Reagent pipetting unit Reagent racks 2 reagent tanks(60ml)/ rack, at most 25 racks
QC racks 24 positions/QC rack, at most 25 racks
Pipetting 8ul~1000ul,1ul stepping,
pipetting precision (100ul )CV≤0.5%
Time to dispense 2 minutes(typical)^100ul of 96 reagents to plate from reagent bottle
Washing unit Programmable Yes(options & parameters)
Wash containers 4 wash buffers at 2.0L, with level-sensing
Waste containers 10L with waste full sensor
Washing system two 8 nozzle manifolds, one to dispense and the other one to aspirate;
Washing residual <2μl
Reading unit Reading system 8 independent photometric channels with mono and bichromatic reading capability
Photometric range 0.000 ~3.000 OD
Spectral range 400-700nm
Optical filters 2 precision filters (450and 630nm); 2 more on request (4 filters max, 405 nm, 450 nm, 492 nm and 630 nm)
Reading inaccuracy inaccuracy±1% from 0.000 to 1.500 OD, ±2% from 1.500 to 3.000 OD
Incubation unit Incubators 4 independent units
Programmable Yes
Temperature range RT to 45 °C
Temperature accuracy ±0.5℃
Temperature staility ±0.5℃
Software unit Software system Windows XP or Windows 7 or above, LIS system available, realize two-way data communications
Function application work list set up, patient reports and result filing; calibration curve, storage for each carried out test
Data reduction cut-off (qualitative)
Physical Specification Power Supply AC220V+ 10%,50/60Hz,450W
Instrument Dimension 110*72*70cm (L*W*H)
Instrument Weight 100kg
Package Dimension 138*91*98cm(L*W*H)
Total Weight 150kg

 

Literature


Fatal error: Uncaught wfWAFStorageFileException: Unable to verify temporary file contents for atomic writing. in /home/accula6/acculabcanada.com/wp-content/plugins/wordfence/vendor/wordfence/wf-waf/src/lib/storage/file.php:52 Stack trace: #0 /home/accula6/acculabcanada.com/wp-content/plugins/wordfence/vendor/wordfence/wf-waf/src/lib/storage/file.php(659): wfWAFStorageFile::atomicFilePutContents('/home/accula6/a...', '<?php exit('Acc...') #1 [internal function]: wfWAFStorageFile->saveConfig('synced') #2 {main} thrown in /home/accula6/acculabcanada.com/wp-content/plugins/wordfence/vendor/wordfence/wf-waf/src/lib/storage/file.php on line 52