AC-HTN Series Horizontal Pulse Vacuum Sterilizer

QUICK OVERVIEW

Product Code: 863
Brand: Horizontal Autoclave

AC-HLN Series

 


Share this product on social networks

AC-HTN Series Horizontal pressure steam sterilizer uses saturated steam as sterilization medium, through the way of gravity exhaust steam to exclude cold air, so that the saturated steam can completely penetrate to the surface of the article, using high temperature saturated steam under high pressure to kill all microorganisms and their spores, the sterilization effect is reliable, is the most effective physical sterilization method.It is widely used in pharmaceutical, biological engineering, laboratory and other fields to sterilize fabrics, instruments, rubber, liquid and other items

nUsing microcomputer control technology, touch screen operation, the whole process (heating, sterilization, exhaust steam, drying) the whole process of automatic program operation.

nTouch screen automatically displays operating status, temperature, pressure, time and other parameters as well as fault alarm information.

nWith fabric, instrument, rubber, liquid, custom 4 sterilization procedures for users to choose.

nBuilt-in high efficiency steam generator, can quickly produce constant pressure steam, do not pollute sterilized goods.

nOptional configuration of micro printer, real-time sterilization process and fault alarm information.

nWhen the program cycle ends, there is a buzzer prompt when the fault alarm occurs.

Safety device :

uOvertemperature automatic protection device: the system automatically cuts off the power supply when the temperature exceeds the setting.

uDoor safety interlocking device: electronic door lock is adopted. Only when the door is closed in place, the sterilizer can start the working procedure. If there is pressure in the inner room or the power supply is not connected, the electronic door lock locks the door handle and the door cannot be opened.

uDry burning alarm device: when the water level is lower than the low water level, the heating power will be cut off automatically and alarm information will be displayed.

uOverpressure relief valve: when the set pressure is exceeded, the relief valve opens to release the pressure.

Electronic circuit safety device: DC control circuit with overvoltage overload

TECHNICAL SPECIFICATION

Model

Volume

(L)

Chamber size

(Φ×L)

Overall dimensions

(L×W×H)

 Weight

kg

Power

AC45-HTN

45

316×590

850×600×520

 60

220V 50Hz  3.6Kw

AC60-HTN

60

380×500

985×600×1450

 100

380V 50Hz  5.7Kw

AC80-HTN

80

386×700

985×600×1450

 115

380V 50Hz  5.7Kw

AC135-HTN

135

500×700

1000×710×1550

 200

380V 50Hz  9.35Kw

AC185-HTN

185

500×950

1250×710×1550

 220

380V 50Hz  10.8Kw

AC300-HTN

300

650×950

1350×900×1750

325

380V 50Hz  12Kw

AC450-HTN

450

650×1360

1750×900×1750

420

380V 50Hz  20Kw

Technical Parameters:

Design pressure

-0.3MPa

Rated working pressure

0.23MPa

Pressure display accuracy

0.1kpa

Sterilization temperature

105 ~ 138℃

Temperature display accuracy

0.1℃

Maximum temperature

138℃

Temperature uniformity

≤±0.5℃

Time of sterilization

0-60 min

Time of drying

0-60 min

Cavity material

SUS304 stainless steel

 


Fatal error: Uncaught wfWAFStorageFileException: Unable to verify temporary file contents for atomic writing. in /home/accula6/acculabcanada.com/wp-content/plugins/wordfence/vendor/wordfence/wf-waf/src/lib/storage/file.php:52 Stack trace: #0 /home/accula6/acculabcanada.com/wp-content/plugins/wordfence/vendor/wordfence/wf-waf/src/lib/storage/file.php(659): wfWAFStorageFile::atomicFilePutContents('/home/accula6/a...', '<?php exit('Acc...') #1 [internal function]: wfWAFStorageFile->saveConfig('synced') #2 {main} thrown in /home/accula6/acculabcanada.com/wp-content/plugins/wordfence/vendor/wordfence/wf-waf/src/lib/storage/file.php on line 52